Encyclopedia of fire safety

Supply ventilation daikin for the apartment. Daikin VAM350FB (supply and exhaust with recovery). Indoor unit with outside air treatment

36 900 rub.

Daikin ATYN25L/ARYN25L wall mounted air conditioner

With automatic mode. with heating mode. Heating power 2800 W. With self-diagnosis function. Noise level 25 dB. Type of the internal block - wall. . Cooling power 2500 W. With auto restart. With remote control. Coolant - R410A. Maximum length communications 20 m. With on/off timer. Served area 25 m 2 . Type of air conditioner - split systems.

buy in online store Ziwo.ru

possible loan

a photo

48 800 rub.

Air conditioner Daikin ATYN25L/ARYN25L Nord-40

With a serviced area of ​​25 m 2 . Auto restart. Auto mode. Mode supply ventilation . With a noise level of 25 dB. On/off timer. With a heating power of 2800 W. Type of air conditioner - split systems. Type of the internal block - wall. With 2500W cooling power. With a maximum communication length of 20 m. Self-diagnosis. heating mode. Remote control. Coolant - R410A.

buy in online store MirCli.ru

loan possible | pickup possible

a photo

48 800 rub.

Daikin ATYN25L/ARYN25L Nord-40 air conditioner 2.6 kW

Type of the internal block - wall. with heating mode. With self-diagnosis function. Noise level 25 dB. With ventilation mode. Cooling power 2500 W. With remote control. The maximum length of communications is 20 m. Heating power is 2800 W. Type of air conditioner - split systems. Served area 25 m 2 . With auto restart. With on/off timer. Coolant - R410A. With automatic mode.

buy in online store Proclimatgroup.ru

possible loan

a photo

RUB 35,040

Wall-mounted air conditioner Daikin ATYN25L/ARYN25L Nord-30

Fresh air mode. Type of the internal block - wall. heating mode. Self-diagnosis. Auto restart. With a heating power of 2800 W. Type of air conditioner - split systems. Coolant - R410A. With a maximum communication length of 20 m. Remote control. With a serviced area of ​​25 m 2 . With a noise level of 25 dB. On/off timer. Auto mode. With 2500W cooling power.

in online store Ziwo.ru

possible loan

a photo

37 900 rub.

Air conditioner Daikin ATYN25L/ARYN25L

with heating mode. Heating power 2800 W. Noise level 25 dB. With ventilation mode. With auto restart. Cooling power 2500 W. Type of air conditioner - split systems. The maximum length of communications is 20 m. Refrigerant - R410A. With automatic mode. Type of the internal block - wall. With remote control. With on/off timer. Served area 25 m 2 . With self-diagnosis function.

in online store MirCli.ru

loan possible | pickup possible

a photo

47 800 rub.

Daikin ATYN25L/ARYN25L Nord-30 air conditioner 2.6 kW

Type of the internal block - wall. Type of air conditioner - split systems. With a maximum communication length of 20 m. Heating mode. On/off timer. Fresh air mode. Self-diagnosis. With 2500W cooling power. Auto mode. Coolant - R410A. With a heating power of 2800 W. Auto restart. With a serviced area of ​​25 m 2 . With a noise level of 25 dB. Remote control.

in online store Proclimatgroup.ru

possible loan

a photo

35 400 rub.

Wall air conditioner Daikin ATYN25L/ARYN25L Nord-40

With self-diagnosis function. With auto restart. With on/off timer. Coolant - R410A. With remote control. Heating power 2800 W. With automatic mode. With ventilation mode. Cooling power 2500 W. Type of air conditioner - split systems. Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Served area 25 m 2 . Noise level 25 dB.

in online store Ziwo.ru

possible loan

a photo

47 800 rub.

Air conditioner Daikin ATYN25L/ARYN25L Nord-30

Remote control. With 2500W cooling power. With a maximum communication length of 20 m. Auto-restart. Type of air conditioner - split systems. With a noise level of 25 dB. Fresh air mode. With a serviced area of ​​25 m 2 . Auto mode. Coolant - R410A. heating mode. Type of the internal block - wall. With a heating power of 2800 W. Self-diagnosis. On/off timer.

in online store MirCli.ru

loan possible | pickup possible

a photo

49 800 rub.

Daikin ATYN35L/ARYN35L Nord-30 air conditioner 3.5kw

The maximum length of communications is 20 m. With self-diagnosis function. Noise level 27 dB. Coolant - R410A. With auto restart. Type of the internal block - wall. With ventilation mode. With automatic mode. Served area 33 m 2 . With on/off timer. Cooling power 3300 W. with heating mode. Heating power 3400 W. With remote control. Type of air conditioner - split systems.

in online store Proclimatgroup.ru

possible loan

a photo

RUB 37,160

Wall-mounted split system Daikin ATYN35L/ARYN35L Nord-30

Type of the internal block - wall. With a serviced area of ​​33 m 2 . Self-diagnosis. Coolant - R410A. heating mode. Auto mode. Fresh air mode. With 3300W cooling power. Remote control. Auto restart. With a heating power of 3400 W. Type of air conditioner - split systems. With a noise level of 27 dB. With a maximum communication length of 20 m. On / off timer.

in online store Ziwo.ru

possible loan

a photo

39 900 rub.

Air conditioner Daikin ATYN35L/ARYN35L

Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Served area 33 m 2 . With self-diagnosis function. With ventilation mode. With auto restart. Noise level 27 dB. With automatic mode. With on/off timer. Heating power 3400 W. With remote control. Type of air conditioner - split systems. Coolant - R410A. Cooling power 3300 W.

in online store MirCli.ru

loan possible | pickup possible

a photo

RUB 67,800

Daikin ATYN50L/ARYN50L Nord-40 air conditioner 5kw

With a serviced area of ​​53 m 2 . Type of the internal block - wall. heating mode. Auto restart. With a heating power of 5500 W. With 5300W cooling power. Fresh air mode. Remote control. Self-diagnosis. Auto mode. Type of air conditioner - split systems. Coolant - R410A. With a noise level of 34 dB. With a maximum communication length of 20 m. On / off timer.

in online store Proclimatgroup.ru

possible loan

a photo

39 300 rub.

Wall-mounted split system Daikin ATYN35L/ARYN35L

Country: Japan; Manufacturer: Japan; Warranty: 3 years; INDOOR UNIT: ATYN35L; Cold, kW: 3.3; Heat, kW: 3.47; Consumption during cooling, kW: 1.08; Heating consumption, kW: 1.08; Energy efficiency EER Cooling: 3.06; Energy Efficiency COP Heating: 3.54; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level bl. Cooling, dBA: 27; Noise level bl. Heating, dBa: 27; Max route length elevation difference, m: 20; d pipes of the freon pipeline, : 6.35 9.5; Dimensions

in online store Ziwo.ru

possible loan

a photo

49 800 rub.

Air conditioner Daikin ATYN35L/ARYN35L Nord-30

Type of the internal block - wall. heating mode. Auto restart. With a heating power of 3400 W. With 3300W cooling power. Remote control. With a serviced area of ​​33 m 2 . Fresh air mode. Self-diagnosis. Auto mode. Type of air conditioner - split systems. With a noise level of 27 dB. Coolant - R410A. With a maximum communication length of 20 m. On / off timer.

in online store MirCli.ru

loan possible | pickup possible

a photo

RUB 66,800

Daikin ATYN50L/ARYN50L Nord-30 air conditioner 5kw

Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Cooling power 5300 W. With self-diagnosis function. With auto restart. With ventilation mode. With automatic mode. With on/off timer. Served area 53 m 2 . Noise level 34 dB. With remote control. Heating power 5500 W. Type of air conditioner - split systems. Coolant - R410A.

in online store Proclimatgroup.ru

possible loan

a photo

RUB 37,510

Wall-mounted split system Daikin ATYN35L/ARYN35L Nord-40

Country: Japan; Manufacturer: Malaysia; Warranty: 3 years; Cold, kW: 3.30; Heat, kW: 3.47; Consumption during cooling, kW: 1,080; Consumption at heating, kW: 0.980; Energy efficiency EER Cooling: 3.06; Energy Efficiency COP Heating: 3.54; Annual energy consumption, kWh: 540; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level bl. Cooling, dBA: 27; Noise level bl. Heating, dBa: 27; Max track length elevation difference, m: 2010; d freon pipes,

in online store Ziwo.ru

possible loan

The HRV system helps create a comfortable environment by interacting with the air conditioning system. The HRV (Heat Recovery Ventilation) system returns thermal energy lost during ventilation and smooths out the change in room temperature caused by ventilation, thereby maintaining a comfortable clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with VRV system®, Sky Air and other systems, automatically switches to ventilation mode, which increases the level of energy saving. The operation of the HRV system is centrally controlled from the console remote control conditioner. This provides simple overall control of air conditioning and ventilation.

These configurations include models with a DX heat exchanger and/or - a DX heat exchanger helps protect personnel from direct exposure to cold airflow during the heating cycle and vice versa. The high static pressure increases the design flexibility of the system.

1. ENERGY EFFICIENCY

More than 30% block size reduction

The use of a high quality paper (HEP) element and optimized design of the fan and airflow channels resulted in a very compact unit while maintaining the 28% reduction in A/C load achieved by previous models. The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of the ventilation mode
- 2% more by controlling pre-cooling and heating (reduces the load on the air conditioning system without an operating HRV system, when the air remains clean certain time after switching on.)

Note: The above values ​​are subject to change depending on the weather and other conditions. environment at the location of the unit

Signature high quality paper (HEP) element

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture absorbing and moisturizing properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of flame retardant material treated with anti-deformation agent.

Operation of the heat exchanger element

Automatic switching to efficient schemes work

During operation, it automatically switches to optimal scheme according to current prevailing conditions



2. DESIGN FLEXIBILITY

Operation at outdoor temperatures down to -15°C

If the outdoor air intake temperature drops below -10°C, the unit will go into intermittent operation, which prevents the heat exchanger element from freezing and causing condensation to form in the unit.

Intermittent operation = thermistor (standard equipment) in the unit detects the outside air temperature. The operation of the unit changes according to the determined temperature.

Compact dimensions

The compact size of the HRV unit allows it to be easily mounted in a narrow space between false ceiling and overlap, as well as in irregularly shaped spaces.


Compact design

The unit can be mounted horizontally or upside down, depending on the installation location. Square manhole 450 mm in size makes it easy to carry out the heat exchanger element.


Quiet operation

Sound pressure levels are very low at 20.5dBA (VAM150FA)


3. CLEAN AIR

Innings fresh air

The user can select 2 fresh air modes with the remote control.


Prevention of dust settling

Prevents dust settling due to direct .

Filter cleaning

The remote control signal indicates when air filter needs cleaning.

CHARACTERISTICS OF THE VKM SYSTEM

1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. By ventilating the rooms where the office equipment is located, which raises the temperature in the rooms, the night mode can reduce the cooling load when the air conditioning system is turned on in the morning.

Freecooling at night only works when connected to multi-unit or VRV® systems.

Freecooling at night is factory set to “disabled” but can be enabled by your Daikin dealer upon request.

Efficient outdoor air preparation with heat exchanger and cooling/heating changeover mode

indoor unit with outside air conditioning.

With outside air, the temperature can be brought up to a temperature close to the room temperature with a minimum cooling capacity.

2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and optimal angle fan spirals, improve work efficiency. Significantly higher static pressure is achieved through improved fan performance. This reduces unit placement restrictions and provides flexible duct design.

Connectivity of indoor units

Connectable indoor units can be up to 130% of the capacity of the outdoor unit

HRV Ventilation units with heat recovery

VAM150FVAM250FVAM350FVAM500FVAM650FVAM800FVAM1000FVAM1500FVAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Air handling units with heat recovery, cooling and humidification

HRV plus DIRECT COOLING AND HUMIDIFYING
VKM50GMVKM80GMVKM100GM
9502 € 10433 € 10900 €

HRV plus DIRECT COOLING
VKM50GVKM80GVKM100G
9129 € 9874 € 10153 €

Daikin Europe NV - subsidiary Daikin Industries Ltd. It is the head office for Europe, Russia, Africa and the Middle East. Funded and has technical support from the Japanese parent company.

Daikin ( Daikin ) was founded in 1973 (Belgium) due to the growing demand in Europe for quality, reliable air conditioning systems. Initially, it was a small assembly plant, which a short time transformed into the most modern air conditioner manufacturing plant in Europe (over 150,000 sq.m.) It manufactures products perfectly adapted to the needs Russian market. Daikin equipment is supplied to many countries around the world.

PRODUCTS

Daikin Europe NV designs and manufactures high technology domestic and industrial air conditioning equipment, air purifiers and ventilation systems , which take the exhaust air from the room and supply fresh air from the street.

Daikin ventilation with heat recovery changes the temperature and humidity of the supply air according to the indoor climate. Due to this, a balance is achieved between indoor and outdoor conditions and the load on the air conditioning system is significantly reduced.
Heat Recovery Ventilation (HRV) units can operate independently or together with the entire air conditioning system. The equipment is used in residential, office and commercial premises, sports facilities, as well as restaurants, cafes and other similar facilities.

Advantages of the HRV system

  • can be installed in a false ceiling or in the floor
  • the most compact equipment in its class
  • efficient heat exchanger
  • the new model has more high efficiency heat exchanger (efficiency of extraction of latent heat and water vapor)
  • moisture removal
  • twice the moisture absorption rate
  • central and centralized control
  • reduction of heat load on air conditioners by 28%

DAIKIN PRODUCT QUALITY

Daikin equipment stands for energy efficiency, energy savings, ease of placement, environmental friendliness, ease of operation, optimal configuration and compatibility of climate equipment.

The recognized quality of the company's products is determined by the special attention paid to the quality of work performed at all stages of production and after-sales service of Daikin equipment. Product quality is confirmed by ISO9001 (guarantees product quality) and EUROVENT certificates (members of this organization voluntarily provide their products for testing and evaluation in independent laboratories of the EUROVENT European Quality Assurance Institute - the only independent certification body refrigeration equipment and air conditioners).

Ventilation units with heat recovery

Characteristics:

  • The compact and energy-saving HRV ventilation system has a wide the lineup(9 models with air flow from 150 to 2000 m3/h). This is very good decision for ventilation of apartments and offices.
  • Permissible outdoor air temperature range from -15 °С to +50 °С. The scope of application has been expanded with the possibility of saving energy.
  • Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms.
  • More efficient and compact heat exchanger. The rate of latent heat and water vapor transfer has been increased, which has made it possible to reduce the dimensions of the heat exchanger by 25% compared to the previous model.
  • Fresh Up mode eliminates hit unpleasant odors from the toilet and cold air through leaks into the room.
  • Possible teamwork air conditioning and ventilation, which increases the efficiency of the climate system and allows you to control:
  1. joint start or shutdown;
  2. the possibility of ventilation control independent of the air conditioner;
  3. changing the ventilation mode (auto/heat exchange mode/no heat exchange);
  4. indication of filter contamination;
  5. change in air flow rate (high/low);
  6. activating the air pre-treatment function before starting the air conditioner.

*- The sound pressure level is measured in the heat exchange mode.

HRV Plus

Ventilation units with heat recovery, cooling and humidification

Characteristics:

  • Humidifier and cooler built into the ventilation unit with heat recovery.
  • Increased free head due to improved fan performance.
  • Heat removal function: the heat accumulated in the room during the day is removed at night.
  • The air handling units are compatible with existing DAIKIN control systems.
  • VKM units can only be connected to VRV outdoor units: RXYSQ-P, RXY(H)QP,
  • REY(H)Q-P, RTSYQ-P and RWEYQ-P(R).
  • The ventilation unit control is designed to work together with the indoor units of the VRV system. The VKM installation and the indoor unit are controlled from one remote control.

AHU

Central air conditioners (ventilation)

Due to the variety of configurations and types of execution, flexibility in the selection of equipment, Daikin central air conditioners can be used:

  • in the domestic sector
  • in retail and commercial areas
  • in public and state institutions
  • at industrial and research facilities
  • in food production
  • medicine and pharmaceuticals.

Daikin's standard range of air handling units (D‑AHU) includes 27 standard unit sizes with air capacities ranging from 1,100 to 124,000 m3/h. In addition, it is possible to manufacture individual sizes with a step of 50 mm, and this does not lead to an increase in cost.

In 2011, Daikin launched a new range of units called the Easy AHU. The productivity of new products is from 500 to 30,000 m3/hour. Easy AHU units are structurally simpler and, accordingly, cheaper than standard ones.

energy efficiency

All installations are designed to meet high energy efficiency requirements. When developing equipment, the thermophysical properties of heat exchange surfaces, the efficiency of electric motors, the degree of filtration, insulation, reduction of friction and pressure drops of the air flow are taken into account. The energy efficiency of installations can be further increased by heat recovery.

Efficient air treatment

Depending on the requirements for air purity, central air conditioners are equipped with filters of various degrees of efficiency:

  • synthetic corrugated
  • flat in aluminum steel mesh
  • compact and soft bag
  • absorption
  • deodorizing

All filters are mounted on commercially available frames with seals.

To prevent dust from entering the air passage when performing Maintenance, the filters are removed from the contaminated side.

The units can be equipped different types and models of humidifiers. Options are available with fully removable humidifiers or with a removable surface evaporation humidifier section.

The units may include heat exchangers with an intermediate coolant or freon, electric heaters, fans, heat recuperators, gas-burners, silencers, controls, automation and security.

D‑AHU units can be combined with chillers and large condensing units, including Daikin inverter condensing units with ozone friendly R‑410A refrigerant.

Variety of designs

The overall dimensions of the central air conditioner can be selected depending on the actual installation conditions. The design is based on a supporting frame and profiles made of aluminum (or anodized aluminum, which is best suited for working in aggressive environments) with a section of 40x40 or 60x60 mm. There are modifications of profiles with a section of 60x60 mm with a thermal insulating insert to reduce heat loss. Profiles with oval inner surface recommended for use in the food industry, medicine, other areas with special requirements to hygiene.

Panels can be flat, 25 and 46 mm thick, or stepped, 42 and 62 mm thick.

Stepped panels allow you to get a flat surface inside the product. Insulation is made of polyurethane foam (40-50 kg/m3) or fibrous mineral wool(90 kg/m3).

Daikin central air conditioners use components produced by companies that are world leaders in their fields: Daikin, Siemens, Belimo, Nicontra, Comefri, Gebhardt.


Modern management

The units are completed with a control cabinet based on a digital controller with all power and control connections. Upon request, the units can be supplied with sensors, servo drives and protective devices. Along with automation, it is possible to order elements of hydraulic piping for water heat exchangers: two- and three-way control valves, pumps, shut-off valves.

Rapid design, installation, commissioning

Daikin VAM-FB– supply and exhaust ventilation unit with heat recovery series HRV, which can be used as part of a multi-zone air conditioning system VRV Daikin. Great option for an apartment country house or office. Supply and exhaust ventilation units HRV corporations Daikin allow you to create ventilation systems with simple and convenient control, with a heat exchange efficiency of up to 80%. The heat exchange unit included in the unit minimizes energy losses in winter period years, transferring heat extract air cold (supply) air flow.

Supply and exhaust Daikin installation VAM1000F/FA/FB with VKM heat recovery perform not only temperature exchange between air streams, but also humidity exchange, and thus “stabilize” the air in the room. The possibility of air humidification is in many cases a decisive factor when choosing Daikin units.

At the same time, it is possible to avoid excessive dryness of the air in the room, since the special material of the heat exchange unit leaves the room not only warm, but also up to 60% moisture. During the summer season, the installation HRV reduces the heat load on the air conditioning system by an average of 20%. This makes it possible to use air conditioners with a lower cooling capacity for the same rooms.

A single control of air conditioning and ventilation will save a few more percent. Additional energy savings can be achieved by using the "Precool/Heat" mode. Under this mode, the start of the ventilation system is delayed in relation to the operation of the air conditioner, which reduces the time required for cooling / heating the room.

Distinctive features: Compact and energy saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is a very good solution for ventilation of apartments and offices.
Permissible outdoor air temperature range from -15 °С to +50 °С. Expanded scope with the possibility of saving energy.
Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms
More efficient and compact heat exchanger. The rate of latent heat and water vapor transfer has been increased, which has made it possible to reduce the dimensions of the heat exchanger by 25% compared to the previous model.
The Fresh Up mode eliminates unpleasant odors from the toilet and cold air from entering the room.
Joint operation of the air conditioner and ventilation is possible, which increases the efficiency of the climate system and allows you to control: joint start-up or shutdown; the possibility of ventilation control independent of the air conditioner; changing the ventilation mode (auto/heat exchange mode/no heat exchange); indication of filter contamination; change in air flow rate (high/low); activating the air pre-treatment function before starting the air conditioner.


ventilation unit Daikin HRV has three ventilation modes, which can be selected by the remote controller of the unit or the remote controller of the indoor unit VRV: full heat exchange mode, when the supply and exhaust air exchange heat and moisture; bypass mode, when supply air is directly supplied to the premises, bypassing the heat exchange unit; automatic mode, when the optimal operating mode is automatically selected based on the room temperature.

Using a bond paper element ( HEP) and optimized design of the fan and airflow ducts resulted in a very compact unit while maintaining the 28% reduction in air conditioning load achieved by previous models.

The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings. Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes: 20% due to operation in full heat exchange mode (compared to conventional fans) 6% due to automatic switching of the ventilation mode another 2% due to pre-cooling control and heating (reduces the load on the air conditioning system without a running system HRV when the air remains clean for a certain time after the air conditioner is turned on.)

Two speeds can be selected using the installation remote control HRV or indoor unit remote control VRV. Selecting the ventilation mode The remote control can be used to set the ventilation mode, in which the supply air supply exceeds the exhaust air flow rate and excludes the possibility of unpleasant odors from the kitchen or toilet entering the room. By changing the remote control settings, you can set the ventilation mode so that the extract air flow is greater than the supply air. In addition to remote control HRV or indoor unit VRV, installation HRV easily integrated into the centralized control system VRVII.

Pre-cooling or pre-heating modes are provided, according to which ventilation is switched on with a certain delay in relation to the moment the air conditioner is started. This significantly improves system efficiency and reduces power consumption.

The HRV system helps create a comfortable environment by interacting with the air conditioning system. The Daikin HRV (Heat Recovery Ventilation) system recovers the heat energy lost during ventilation and smooths out the change in room temperature caused by ventilation, thereby maintaining a comfortable clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with the VRV® system, Sky Air and other systems Daikin air conditioning, automatically switches to ventilation mode, which increases the energy saving level. The operation of the HRV system is centrally controlled from the remote control of the air conditioner. This provides simple overall control of air conditioning and ventilation.

These configurations include models with a DX coil and/or humidifier - the DX coil helps protect personnel from direct exposure to cold airflow during the heating cycle and vice versa. The high static pressure increases the design flexibility of the system.

1. ENERGY EFFICIENCY

More than 30% block size reduction

The use of a high quality paper (HEP) element and optimized design of the fan and airflow channels resulted in a very compact unit while maintaining the 28% reduction in A/C load achieved by previous models. The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of the ventilation mode
- another 2% by pre-cooling and heating control (reduces the load on the air conditioning system without an operating HRV system, when the air remains clean for a certain time after switching on air conditioner.)

Note: The above values ​​may vary depending on the weather and other environmental conditions at the location where the unit is installed.

Signature high quality paper (HEP) element

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture absorbing and moisturizing properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of flame retardant material treated with anti-deformation agent.

Operation of the heat exchanger element


Automatic switching to efficient work patterns

During operation, automatic switching to the optimal scheme takes place in accordance with the current dominant conditions



2. DESIGN FLEXIBILITY

Operation at outdoor temperatures down to -15°C

If the outdoor air intake temperature drops below -10°C, the unit will go into intermittent operation, which prevents the heat exchanger element from freezing and causing condensation to form in the unit.

Intermittent operation = thermistor (standard equipment) in the unit detects the outside air temperature. The operation of the unit changes according to the determined temperature.

Compact dimensions

The compact size of the HRV unit allows it to be easily installed in narrow spaces between suspended ceilings and ceilings, as well as in irregularly shaped spaces.

Compact design

The unit can be mounted horizontally or upside down, depending on the installation location. The 450 mm square inspection hatch makes it easy to carry out service and replacement heat exchanger element.

Quiet operation

Sound pressure levels are very low at 20.5dBA (VAM150FA)

3. CLEAN AIR

Fresh air supply

The user can select 2 fresh air modes with the remote control.

Prevention of dust settling

Prevents dust settling due to direct installation of air ducts.

Filter cleaning

The signal from the remote control indicates when the air filter needs to be cleaned.




CHARACTERISTICS OF THE VKM SYSTEM


1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. By ventilating the rooms where the office equipment is located, which raises the temperature in the rooms, the night mode can reduce the cooling load when the air conditioning system is turned on in the morning.

Freecooling at night only works when connected to multi-unit or VRV® systems.

Freecooling at night is factory set to “disabled” but can be enabled by your Daikin dealer upon request.

Efficient outdoor air preparation with heat exchanger and cooling/heating changeover mode

Indoor unit with outdoor air preparation.

With outside air, the temperature can be brought up to a temperature close to the room temperature with a minimum cooling capacity.


2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and an optimized fan helix angle, result in increased efficiency. Significantly higher static pressure is achieved through improved fan performance. This reduces unit placement restrictions and provides flexible duct design.


Connectivity of indoor units

Connectable indoor units can be up to 130% of the capacity of the outdoor unit

Prices for Daikin air handling units

HRV Ventilation units with heat recovery

VAM150F VAM250F VAM350F VAM500F VAM650F VAM800F VAM1000F VAM1500F VAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Air handling units with heat recovery, cooling and humidification

HRV plus DIRECT COOLING AND HUMIDIFYING
VKM50GM VKM80GM VKM100GM
9502 € 10433 € 10900 €

HRV plus DIRECT COOLING
VKM50G VKM80G VKM100G
9129 € 9874 € 10153 €

Similar posts