Fire Safety Encyclopedia

Error codes for the gas boiler Neva Lux - malfunctions and what to do in a specific situation. Errors of gas water heaters Neva Lux Neva Lux boiler error 03 what to do


Gas wall-hung boilers Buderus
Logamax models U042, U044, GB072, GB172. With open and closed combustion chamber. Repair and service methods, adjustment of operating parameters. Maintenance recommendations.
Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, maintenance, settings of functional components. Hydraulic diagrams.
Ariston gas wall-hung boilers
Clas, Clas Evo, Genus models. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods.
Gas boilers Immergaz
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Metos. Repairs and adjustments. Installation, assembly and connection. Settings for operating modes and accessories.
Kentatsu Furst boilers
Wall models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.


Errors of the Neva Lux boiler and their meanings

Error 01 (E2)- Malfunction associated with unsuccessful ignition or overheating of the heating medium. The boiler is not functioning.

Code 01 for models Neva Lux 7023, 7224, 8224. Code E2 - Neva Lux 8023, 8029.

Burner clogged. Clean burner and nozzles. The ignition electrode is faulty, its electrical circuit is broken, the gap between the ignition electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (4-5 mm). Replace the ignition electrode. The ignition transformer is defective or its electrical circuit is broken. Check the electrical circuit and connector contacts in the control unit. Check and, if necessary, replace the ignition transformer. The ionization electrode is faulty, its electrical circuit is broken, the gap between the ionization electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (3-3.5 mm). Replace the ionisation electrode. Also, in case of error 01 (E2), the coolant overheating sensor in heating mode may be triggered. Find and eliminate the cause of the coolant overheating. The coolant overheating sensor is faulty or its electrical circuit is broken. Check the electrical circuit and contacts. Inspect the overheating sensor (must be closed at temperatures up to
95C). No flame due to gas valve failure. Check for contact in the valve connector and in the control unit. Replace the valve if necessary.

Error 02 (E7)- Overheating of the coolant

Code 02 for models 7023, 7224, 8224. Code E7 - models 8023, 8029.

The fan is damaged (the motor winding is burnt out, the bearing is jammed, the impeller is jammed, the fan's electrical supply circuit is broken). Check the continuity of the circuit and contacts in the connections. Ensure free rotation of the impeller. Replace fan if necessary. Also, in case of error 02 (E7), the coolant overheating sensor may be faulty or its electrical circuit may be broken. Check the electrical circuit and contacts. Check the overheating sensor (should be closed at temperatures up to 95C). The coolant overheating sensor has triggered in heating mode. Find out and eliminate the cause of the coolant overheating.

Error 03 (E6)- Malfunction in the flue gas removal system

Code 03 for models 7023, 7224, 8224. Code E6 - models 8023, 8029.

Clogged chimney or supply air duct. Clean pipes. The supply pipes or the housing of the air pressure switch are damaged. Repair damage or replace tubing. The electrical circuit of the air pressure switch has broken. Air pressure switch defective. Check the continuity of the circuit and contacts in the connections. Replace the sensor.

Error 04 (E1)- Lack of water pressure or lack of circulation in the heating circuit. The device does not start.

Code 04 for models 7023, 7224, 8224. Code E1 - models 8023, 8029.

Small amount of water in the heating system. Top up the heating medium in the heating circuit to the required pressure. There is air in the heating system. Remove air from the heating system. Clogged dirt filter in the heating circuit. Clean the filter. Defective or incorrectly installed bypass valve. Check and, if necessary, replace the valve. Failure of the circulation pump. Replace the pump. Even with error 04 (E1), there is insufficient mobility or souring of the stem of the flow sensor in the heating circuit, which transfers movement to the microswitch, rupture of the membrane of the flow sensor. Remove the microswitch from the flow sensor housing. By switching the boiler on and off again (turning on and off the pump), release the stationary stem; if this does not help to check the integrity of the membranes on the flow sensor. The microswitch is defective, or the electrical circuit between the microswitch and the control unit is broken.
Check the electrical circuit and contacts in the connector of the control unit. Replace microswitch. Failure of the servo motor of the three-way valve drive. Replace the servomotor. Gas supply interrupted. Check the presence and pressure of gas at the inlet to the gas unit. Click on the Reset button. Incorrect phase connection when connecting the unit to the mains. Make the correct connection of the phases.

Error 05 (E3)- Failure of the heating circuit temperature sensor. The appliance does not work in either heating or DHW mode.

Code 05 for models 7023, 7224, 8224. Code E3 - models 8023, 8029.

The temperature sensor of the heating circuit is defective. Replace temperature sensor. Violation of the electrical circuit temperature sensor - control unit. Check the electrical circuit and contacts.

Error 06 (E4)- Damaged DHW temperature sensor. The boiler will continue to operate in heating mode and in hot water supply mode.

Code 06 for models 7023, 7224, 8224. Code E4 - models 8023, 8029.

DHW temperature sensor malfunction. Replace the DHW temperature sensor. Damage in the electrical circuit DHW temperature sensor - control unit. Check the electrical circuit and contacts.

Error E8- Communication error

The loop connecting the controller board with the control board is damaged, or there is no contact in the loop connectors. Check the integrity of the loop and the presence of contact in the connectors. Replace the ribbon cable if necessary. Control board malfunction. Replace the board. Faulty controller board. Replace the board.

Error E9- Supply voltage out of permissible limits

The boiler supply voltage is outside the range of 180 - 250 V. When the normal supply voltage is restored, the device will turn on automatically.

Troubleshooting

For 2 years I have been using a Neva Lux gas boiler manufactured by Baltgaz. Now defects began to appear in his work. If you use hot water for a long time, the pressure in the system drops, and it stops by mistake 04. Although the pressure gauge shows the same pressure of 1.6 bar. Has to
constantly use make-up. How can I fix this?

Perhaps the pressure in your expansion tank is lower than it should be. This is when error 04 is possible.

Six months ago, I installed a double-circuit boiler Neva Lux 8230. Recently I encountered such a problem. When hot water was required, I turned on the tap as usual. At first it went warm, and then cold again. Error 02 appeared on it at that moment. I tried to reset it with the "reset" key, but after that the heating turned on. After that, hot water was required again in the evening. I turned on the tap and everything worked fine. The device worked for 4 days without problems, but today the error appeared again. I studied it more carefully. It happens like this. After the transition to heating water for DHW occurs, a sound is heard inside, similar to air intake. At the same time, you can observe the instability of the manometer readings (approximately 0.5 in each direction). And all this is accompanied by the same strong sound not only from itself, but also from the membrane tank (additional, external for 18 liters). After that, the pressure rises sharply to 5 bar. Shutdown occurs, the water temperature drops to 23C. And error 02 is displayed. The instructions say that I have air in the heating system, but I work with hot water supply. What's the connection? Maybe my 3-way valve is broken? Or is the filter in the heating system clogged?

Error 02 - the coolant is overheating. The fan may be broken or the sensor may be damaged.

My boiler Neva Lux 7023 stops about 2 times a month by error 07. Restarting always solves this problem. And now a new error has appeared - E5. It works for a quarter of an hour and turns off. What happened to him?

Error E7 means that the coolant is too overheated. Perhaps your heat exchanger is covered with scale on the inside, and because of it there is poor circulation in the system. Has he started making some unusual noise for you? But regarding the E5, here you need to pay attention to the pressure switch or the fan. It is necessary to look at both that and that. In an amicable way, this problem should be solved by a specialist. Also, just in case, check if your chimney is icy.

The unit showed error 03. As I understand it, it means problems with the fan. When checking, I applied voltage to it - everything is normal. I also checked the pressure switch - it is also serviceable. Is there a relay on the board? A couple of years ago I came across a similar one. But then an acquaintance helped me out, giving from his old unit. Tell me, is it possible to work somehow without this relay? I tried to manually spin the fan, it started to work, but no gas came. Is the same relay responsible for this? But now the error was 01.

In order for the relay to work longer, it is necessary to adjust the gas valve and heating power more carefully, and it is also advisable to install a room thermostat. All this not only increases the service life of the device, but also saves gas. To solve error 01, you need to check the voltage on the gas valve, whether it opens normally and whether gas is flowing. It is better to call a specialist, as all these checks are life-threatening. And the master has a differential. pressure gauge for assessing gas pressure. And so, most likely you have a small house and you did not set up the system for the heated area. So a room thermostat is the best solution for you.

Help me please. In our new apartment, even before us, a wall-mounted double-circuit NevaLux 7218 was installed. During the day, it constantly stops by mistake 04. They began to feed, then the temperature began to drop. And now water has also flowed out of it (in the place where the heating pipe enters it). I had to turn it off. So you can't use it?

It is necessary to check the pressure switch. In the chimney, a small air exhaust pipe could be blocked.

My wall-mounted boiler Neva Lux 7023 (Baltgaz) has a problem with hot water supply. With heating, everything is normal, and as soon as I start parsing water, an error E2 appears. This does not heat up the water. If the water is turned off, then it is perfectly normal to continue heating the apartment. The water pressure is consistently good. I looked in the instructions, it says that E2 is an error of unsuccessful ignition or overheating of the coolant. During DHW operation, the burner starts working and burns for 2 seconds. Then the thermometer shows a temperature of 95C, immediately turning off the device and an error. The water runs warm while the burner is on. What could have broken?

Try to check the DHW temperature sensor, perhaps this is the case. Although, in theory, the E2 error symbolizes problems with ignition, but then there would be no heating.

My wall-mounted Baltgaz boiler at first did not want to switch from heating system mode to hot water supply. Although, sometimes, for reasons I do not understand, it still worked as it should. First of all, I checked that all contacts were in good working order, then I checked the electric motor of the three-way valve. If you clamp it with a screwdriver, then the valve is in good order and works as it should. If you switch the mode (with the engine removed), then everything works. The movement of the stem is noticeable and consistent. I contacted the service center. The master who came to me suggested that the problem was in the flow sensor. He did not see the signal coming to him. We need a new one. But he did something to make the device work. It did not work for a day, and then I needed to turn it on. And it doesn't start. The indicator blinks, all possible symbols are highlighted. The reboot did not help. Disconnecting the power supply did not help either. What could be the problem?

Take out the connector on the board, and disconnect the wires one by one. First of all, those that are responsible for the drive of the three-way valve. Then reattach them. This should fix your problem.

I just can't fix the Baltgaz Neva boiler. Error 03 constantly appears, the fan does not work during ignition. If you blow on the pressure switch tube, then it starts spinning. The device does not want to turn off on its own, you have to do it manually. How to be?

Find the hatch in the upper right corner. You need to open it and restart it.

Other malfunctions

Lack of spark for ignition.

Ignition plug defective or poorly installed. Correctly install the plug (gap between the end of the plug and the burner section 4-5 mm) or replace it. Loose contact between terminal and ignition wire. Check the contact of the terminal with the ignition wire. The ignition electrode is dirty. Wipe the electrode from dust and degrease.

The boiler does not turn on.

Lack of gas. Lack of water. Lack of electricity. Carry out appropriate checks (incoming gas, presence of water, connectors, fuses). Burner nozzles clogged. Clean the nozzles.
Air in the gas circuit. (May occur after prolonged inactivity). Turn on the unit several times until the error is eliminated. Fuse blown. Replace the fuse on the controller board. The temperature sensor of the heating circuit has been triggered. Check pump operation. If the pump is running, check the sensor. Defective gas valve. Repair or replace the valve. Deactivated boiler. Switch on the device again.

Pops in the burner.

Gas supply problems. Check the gas pressure upstream of the unit. Dirty burner. Check and clean the burner. Insufficient air supply. Clean the burner. Poor flame control. Check gas flow and gas pressure upstream of the burner.

Smell of gas.

Gas leak. Check the entire gas circuit for leaks using soapy water or a gas detector.

Little or no hot water output.

Insufficient inlet water pressure. Increase pressure by installing an additional inlet pump. Clogged water filter. Remove and clean the filter on the DHW line. Heat exchanger with partially or completely blocked tubes. Clean the heat exchanger tubes.

Cold radiators in winter.

The heating temperature is set too low or the temperature sensor is faulty. Set a higher heating temperature or replace the temperature sensor. The pump is not working due to contamination. Remove the screw at the front of the pump and turn the spindle.

Hot radiators in summer

Winter heating mode. Set summer mode.

___________________________________________________________________________________________

___________________________________________________________________________________________

Borino, ZhMZ, Siberia, Alpha Calor, Thermotechnik.
Adjustment of gas automatics Eurosit 630. Replacement of the thermocouple and maintenance of the ignition burner.

Codes of errors and malfunctions of boilers Neva Lux

The shutdown of the Neva Lux boiler, caused by a failure or malfunction of any of its systems, is accompanied by the corresponding error code flashing on the control panel display, which makes it easier to detect the malfunction.

Error codes, possible causes and troubleshooting methods

Error 01- Problems related to unsuccessful ignition. The boiler is not working.

Gas supply failure - Open the shut-off valve on the gas pipeline, or check the pressure in the cylinder (LPG.)

Ignition plug defective - Replace spark plug.

Spark plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between spark plug and burner section - Set gap (5 + 0.5 mm).

The spark from the spark plug electrode jumps onto the combustion chamber shell - Bend the combustion chamber shell at the place where the spark plug is installed.

The spark plug is dirty - Wipe the spark plug from dust and degrease.

Ionisation plug defective - Replace plug.

Ionisation plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between ionization plug and burner section - Set gap (3 + 0.5 mm).

Ignition transformer defective - Replace the Neva Lux boiler ignition transformer.

The electrical circuit of the ignition transformer is interrupted - Check the electrical circuit and contacts.

Burner block clogged - Clean burner block.

Gas regulator electrical circuits interrupted - Check electrical circuits and contacts.

Error 02- Overheating of water. The boiler is not working.

Clogged heating system - Clean the heating system.

Thermal relay defective (normally closed at temperatures up to 90 ° C) - Replace the thermal relay.

Filter in heating system clogged - Clean filter.

Defective or incorrectly installed, bypass valve - Check that the bypass valve parts are correctly installed and replace if necessary.

Defective pump or vent valve - Replace pump or vent valve.

Defective pump relay on the electronic board - Replace the electronic board.

Gas regulator not working - Replace gas regulator.

Gas regulator not adjusted - Adjust gas regulator.

Thermal relay (overheating sensor) electrical circuit broken - Check electrical circuit and contacts.

Error 03- Lack of traction. The Neva Lux boiler does not work.

Chimney or air duct blocked - Find out the cause of the blockage and remove it.

The tightness of the pressure switch tubes is broken - Replace the tubes.

Violation of the electrical circuit of the pressure switch - Check the electrical circuit and contacts.

The pressostat is faulty (the pressostat contacts should close at a pressure drop of 130 Pa) - Replace the pressostat.

Condensation in the pressure switch tubes - Remove condensation from the pressure switch tubes.

Violation of the electric circuit of the fan - Check the electric circuit and contacts.

Fan defective - Replace fan.

Error 04- Insufficient water pressure in the heating circuit. The boiler is not working.

Reduced water pressure in the heating circuit - Bring the water pressure in the heating circuit to the recommended value.

Air lock in the heating system - Open the air bleed valve.

The water pressure sensor in the heating circuit is faulty - Replace the sensor.

Defective pump or vent valve - Replace pump or vent valve.

The electrical circuit between the pressure sensor and the electronic board is broken - Check the contacts of the connectors in the control unit and on the sensor and the sensor circuit.

Error 05- Failure of the heating circuit temperature sensor. The boiler is not working.

Heating circuit temperature sensor defective - Replace the heating circuit temperature sensor.

Electrical circuit "temperature sensor - electronic board" broken - Check the electrical circuit and contacts.

Error 06- Failure of the DHW temperature sensor. The Neva Lux boiler works only in heating mode.

DHW temperature sensor defective - Replace DHW temperature sensor.

The electrical circuit between the DHW temperature sensor and the electronic board is broken - Check the electrical circuit and contacts.

Error 07- Malfunction of the gas regulator modulator coil. The boiler is not working.

Broken gas regulator modulator coil - Replace gas regulator (modulator coil resistance 80 Ohm).

Electrical circuit "modulator coil - electronic board" broken - Check the electrical circuit and contacts.

Malfunctions of boilers Neva Lux without an error code

Neva Lux boiler does not turn on

Lack of electricity - Contact the electricity service.

Fuse blown - Replace the fuse on the board.

Water ingress on the electronic board - Dry the board with warm air or leave it for two days in a dry place to completely evaporate the water.

Failure of the electronic board (RESET does not help) - De-energize and restart the boiler or replace the electronic board.

Claps in the burner

The minimum gas pressure and ignition power are set incorrectly - Adjust the minimum gas pressure and ignition power.

Insufficient air supply - Clean the air intake pipe or duct.

The spark from the electrode of the spark plug jumps to the edge of the burner section or to the shell of the combustion chamber - Bend the spark plug or bend the shell of the combustion chamber, ensuring spark slip into the area of ​​the holes in the nozzle of the burner section.

Dirty burner block - Clean burner block.

Gas smell

Gas leaks - Check the entire gas circuit for leaks, eliminate gas leaks.

Little or no hot water output

Insufficient water pressure at the inlet to the hot water supply - Contact the housing and communal services service.

Water filter clogged - Clean DHW filter.

Heat exchanger clogged - Clean the heat exchanger.

The set temperature of hot water is not maintained (too high)

High inlet water temperature - Increase the flow of water through the DHW circuit or dilute the hot water with cold water, avoiding a decrease in the flow through the DHW circuit.

Small water flow through the DHW circuit - Increase the water flow through the DHW circuit.

Neva Lux boiler does not work in heating mode (but works in DHW mode)

Room thermostat jumper missing - Install the room thermostat jumper.

The room thermostat jumper connecting the contacts is faulty - Replace the room thermostat jumper.

Room thermostat defective (if a thermostat is installed) - Replace the room thermostat.

The temperature of the water entering the heating system is lower than the set

Heating circuit temperature sensor defective - Clean the temperature sensor from scale (if using an immersion temperature sensor), or replace the temperature sensor.

The boiler is in standby mode, the display shows the symbol "- -" and the boiler does not respond to pressing the control buttons

The supply voltage has gone beyond 190 ÷ 250 V - Restore the supply voltage within 190 ÷ 250 V. After 30 seconds, the boiler will automatically start in the mode in which it was before the voltage went beyond 190 ÷ 250 V.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

In chapter Service, maintenance and repair to the question Boiler neva lux 8224. constant error 03. condensate accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, outside temperature, fuel (gas or diesel fuel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensate from collecting in the pitot tubes? The Neva Lux 8224 boiler turns off every year in January, showing error 03. Of course, I eliminate the condensate and start the boiler until the next accumulation of condensate, but this problem is pretty boring. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed.
make-up.
2. If the make-up valve is closed all the way, then
it is possible that the make-up valve is not tight.
Replace the make-up valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: opening the plug on the right side
at the top in order to enter the combustion chamber
warm air and not
condensation formed in the presostat tubes.


What does error 01 mean, how to troubleshoot the Neva Lux repair?

Double-circuit gas boilers Neva Lux 8624, 8230, 8224 are wall-mounted apparatus with forced circulation of the coolant (water or antifreeze). Repair and maintenance of Neva Lux boilers is carried out according to the service instructions by a specialized service organization that is also engaged in the installation, commissioning and service work with the supply, replacement of faulty parts with new parts of this Neva Lux heating equipment.

So, with error 01, the flame does not ignite in the combustion chamber or the ignition starts, but it turns out to be unsuccessful - the Neva boiler does not work. Concisely, in this case, one or several reasons for error 01 may be present. Let us consider all the causes of the emergency and give a full range of recommendations for repairing the Neva Lux gas boiler in the event of error 01. Technical information is provided for service engineers of organizations for the repair of gas equipment.

Error 01 in the electronic control board is often found when repairing gas boilers from various manufacturers of electronic heating equipment with electronic control. The first common malfunction, the lack of ignition, is the incorrect operation of the entire chain of volatile and mechanical actions, from the pilot to the main gas burner. Similar problems during the occurrence of error 01 relate to wall-mounted boilers Visman Vitopend 100, Baksi, Kiturami, Electrolux, Ariston, Immergaz, Neva Lux 8224 and other models of various manufacturers. When inspecting the gas appliance, it is necessary to make sure that all the manufacturer's recommendations for installing a gas boiler are followed: electricity, electronics, gas, chimney, air flow, correct installation of the Neva Lux boiler according to the installation diagram and the rules of the gas economy.

Repair of the gas boiler Neva Lux with error 01 information begins with checking the gas supply to the heating boiler fittings. Next, we check all RTs for operating condition, observing the contact ability of the relay. Gas modulator valve diagnostics, static and dynamic pressure check. By default, the elements of ignition, ionization are subject to inspection and maintenance. In this case, the gaps with respect to the burner section along two electrodes must be observed. Eliminate distortions and mechanical damage that interfere with the correct settings of the boiler. Diagnostics of the ignition transformer unit (coil), if there is no power to the ignition electrode.

During the repair of the Neva Lux boiler, which runs on liquefied gas, it is necessary to prepare documents for the last refueling of the gas tank (technical data of the fuel), a contract for those. maintenance of the gas boiler and call a service technician for diagnostics and repair of gas. apparatus.

Timely, constant maintenance of gas boilers Neva Lux gives uninterrupted operation of equipment, warmth and comfort in your homes. By carrying out scheduled repairs, the necessary replacement of spare parts, you extend the life of the Neva Lux boilers and make the right investment.

The Neva Lux gas water heater from a domestic manufacturer is a technically complex product. The whole cycle of work from turning on the column to heating the water is controlled by automation, which malfunctions over time. For a better understanding of the malfunction, the company's engineer placed an indicator window on the front panel, in which one or another error code is displayed during an emergency stop. Let's consider them in more detail.

ATTENTION! Maintenance operations for the repair of gas water heaters associated with the disassembly of its gas or water communications must be performed by qualified craftsmen. Self-repair can have the opposite effect, before buying a new unit.

Error E0 - lack of gas

Reason # 1. NSTurn off the gas at the descent to the column or light the gas stove. Lack of gas in the gas pipeline due to work on the pipeline. The servo motor (block with solenoid valves) is out of order.

This error cannot be eliminated on your own. You will need the help of a service worker. Contact a specialized service center for repair.

Error E1 - no flame

Ignition clicks for about a minute the burner does not ignite. The electronic control unit does not see the presence of a flame and the column goes into emergency mode.

Reason # 1. The presence of air in communications... Didle column, or after its installation, the operation of the ignition burner will occur only after air has been removed. The system should be purged by constantly turning on the column. Since the ignition lasts no more than a minute, after completion you should reopen the water tap until the ignition occurs.

Reason # 2. Lack of gas in the cylinders or the valve on the lowering to the dispenser is closed... NSOpen the shut-off valve fully. Check LPG cylinders. Replace them if necessary.

Reason number 3. There is no contact between the unit and the flame sensor... It is necessary to service the contacts coming out of the electronic unit, if necessary, clean them, tighten them for a good connection, replace the worn ones.

Reason number 4. Flame presence sensor outside the flame zone... Adjust the position of the flame detector so that its electrode is in the gas combustion zone. Make sure that the electrode does not touch other metal components. Clean the electrode from carbon deposits.

Reason number 5. The gap between the ignition plug and the igniter is broken... From constant heating and cooling, the pilot burner nozzle is deformed, which increases the gap to the spark plug. Every two years, or with a regulated maintenance, the gap should be adjusted 4 ... 5 mm.


Error E3 - breakdown of automation

The solenoid valves are triggered before the signal from the water flow sensor appears.

Reason # 1. Breakage or malfunction of solenoid valves... Call the wizard for diagnostics.

Reason # 2. Electronic control unit defective... Invite the master to the house.

Error E4 - premature inclusion

The flame detector generates a flame signal until the signal from the water flow sensor appears.

Reason # 1. You are trying to turn on the speaker using a different power source (matches).

Reason # 2. The electronic control unit is out of order.

Error E5 - no signal from the flow sensor

There is no signal coming from the water flow sensor (open circuit).

Reason # 1. Open circuit between the electronic unit and the water flow sensor... Use a tester to check the circuit and also check the sensor for an open.

Error E7 - lack of gas

The column goes out after switching on. Failed ignition attempt. Process: the igniter is ignited, then the main burner, then everything goes out and the process is repeated again.

Reasons # 1. Low gas pressure... Open the gas cock at the lowering to the column. Invite a specialist to your home to measure the gas pressure in the system and further configure the column. You should also purge and clean the gas filter.

Reason # 2. The flame ionisation sensor is not in the range of the main burner fire... Adjust the sensor. Install the electrode so that the main burner fire flushes from both sides. Carbon deposits may have formed on the sensor, which makes heating weak - clean and adjust the sensor.

Reason number 3. The mechanism in the water unit is stuck... Increased salt deposition on moving machinery leads to seizing and stopping. A stuck rod of the water unit leads to a permanent closure of the flow sensor. In this case, it is necessary to dismantle the water part and carry out preventive work: lubrication of the rod, replacement of rubber gaskets.

Error E8 - no traction

The column turns off after 2..5 minutes of work. Restarting becomes possible only after cooling down - 2..3 minutes.

Reason # 1. Lack of draft in the chimney... Clean the chimney.

Reason # 2. Soot on the heat exchanger... Increased accumulation of soot on the heat exchanger, which prevents the passage of carbon monoxide into the chimney. To fix the problem, the column should be serviced.

Reason number 3. The traction sensor is faulty... The traction sensor works for rupture. Over time, the sensor becomes very sensitive to vibrations and can turn off the column during heating. Therefore, with this error, the sensor will be checked for operability.

Error 99 - short circuit

Numbers 99 blink on the display for a while, then the column turns off with an error message LO.

Reason # 1. Closed the water temperature sensor(makes sure that the heat exchanger does not overheat). The error can be eliminated only by replacing the sensor and its wires.

Error H1 - insufficient heating

The column does not heat the water to the specified temperature.

Reason # 1. High temperature set at high head. The column cannot cope with heating the amount of water that passes through the column. Reduce head.

Reason # 2 ... Burner clogged with dust. If you notice that the gas is burning orange, and the flame is sluggish and elongated, then it's time to clean the burner. If you neglect cleaning, then this error will appear constantly. The efficiency of the column will be halved. A lot of soot will appear.