Fire Safety Encyclopedia

Wall mounted gas boilers Baxi with weather-dependent automation. Protection against scale formation in boilers BAXI MAIN Four

Reliable

Equipment

Top quality materials
... Components from manufacturers of world leaders (Siemens, Honeywell, Sit, Grundfos, Alfa laval, Zilmet)

Production

Years of experience
. Modern system organization of production and product quality control
(ISO 9001 since 1993)

Adapted to conditions in the Russian Federation

Work at low pressures gas
... With an inlet gas pressure of 5 mbar, 50% of the rated power is ensured

Chart for BAXI MAIN Four

Easy to install

In the box with each boiler there is a fixing template
... Durable protective film on external panels boiler


Service friendly

Access to all elements through the front panel
... You can quickly replace any element with simple tools
... Electronic self-diagnosis


Modern automation

Intuitive controls


Modern BAXI automation

1. All single-circuit models can work with a storage boiler

2. Built-in weather-dependent automation

Saves fuel by reacting quickly to changes in outdoor temperature
... Increased comfort

3. Possibility of installing a room thermostat

Mechanical or electronic programmable thermostat
... Contacts for the thermostat are available in any BAXI boiler

4. Progressive automation on boilers of the LUNA-3, NUVOLA-3 series and condensing boilers

Remote control of the boiler
... Daily and weekly programming of the heating and DHW circuit
... Built-in room temperature sensor
... Self-adapting weather curve
... Correction of the weather curve for room temperature
... Wireless control capability
... Accounting for building inertia and other functions


5. Correction and self-adaptation of the weather-dependent curve by the room temperature sensor

Perfect heat release without overheating
... Boiler modulation in operation


6.. Dispatching capability


... There is an input contact for working together together with solar panels

The board allows you to send a signal about blocking the boiler to the dispatcher's console or GSM module

7.. Protection against limescale formation in boilers BAXI MAIN Four

Each temperature rise (> 95 ° C) in the heating circuit reduces the DHW temperature by 3 ° C (the DHW temperature stops decreasing at 42 ° C). If the water temperature in the heating circuit exceeds 95 ° C twice, the top two indicators on the control panel will flash, signaling the need to clean the heat exchanger.

8. Anti-freeze system


... If the temperature in the heating circuit or in the DHW circuit drops below + 5 ° C
... The boiler will automatically turn on and heat up the system circuit up to + 30 ° С


nine. . Blocking protection system for pump and 3-way valve

The boiler must be connected to electricity and in good working order
... The boiler has not started for more than 24 hours
... The boiler automation turns on the pump and switches the stem of the three-way valve, preventing the “sticking” of the moving parts of these elements

10. Antibacterial protection system

Works only when connecting a DHW boiler
... Designed to kill pathogenic bacteria, especially Legionella
... At the first start, it is activated after 1 hour
... Once a week, the boiler heats up the boiler to the highest possible temperature

Note: If necessary, it is possible to disable this function.

Wide model range

Traditional wall mounted boilers - 31 models

In this article, using the example of gas wall-mounted boilers Baxi model rows Luna 3 Comfort, Main5 and Luna Duo-Tec MP (fig. 1) shows how remote control boiler through the system home automation("Smart home") Z-wave standard.

Rice. 1. Boilers Baxi model series Luna 3 Comfort, Main5 and Luna Duo-Tec MP

Usually, gas boilers used to provide country house warm, tuned in permanent job in the optimal mode, in which the least amount of fuel is consumed to obtain a unit of thermal energy per unit of time. But continuous work even in this optimal mode, it will lead to a significant overspending of gas, because there is no constant need for this amount of heat. Why constantly supply heat to the radiators, especially if there is no one in the house? Without harm to the house (the risks of "defrosting" of the heating circuit are leveled by the automation of the boiler itself), you can turn off the heating of the heating circuit during the absence of people in the house. As a rule, with good thermal insulation of the house, the decrease in the air temperature in the room within 6 hours will be no more than 2 ° C. And the heating radiators are capable of increasing the air temperature in the room by 2-2.5 ° C per hour.

Remote control gas boiler provides, in addition to ease of management and comfort, a significant benefit - there is no need to burn gas when you do not need to constantly maintain high fever heating batteries (for example, in the morning you left for work, there is no one in the house). You can transfer the boiler to the heating circuit heating mode in order to quickly increase the temperature in the house (for example, before leaving work, before arriving at the house) at any time if there is an Internet connection in the house - you can set up access from mobile phone... It is also possible to set an automatic scenario of switching on / off the boiler by the automatic control system smart home"Linked to the calendar.

Boiler controller boards of the Luna 3 Comfort, Main5 and Luna Duo-Tec MP models have connectors that allow “heat request” from the home automation system, bypassing the boiler's automation.

Here we will show an example of connecting wall-mounted gas boilers of different models from Baxi to a home automation system. Let's consider the implementation of the following functions:

  • remote control of the gas boiler operation by “heat demand” (via the “heat demand” terminals) to ensure gas consumption savings;
  • remote control of coolant temperatures in the heating circuit;
  • monitoring the integrity of the boiler circuit;
  • remote reading of gas meter readings;
  • timely notification of leaks (in the boiler room, where the a large number of pipes, connections and equipment) and the emergency state of the boiler.

The tasks can be accomplished by installing the DCM-5.1.1-Z data acquisition module (equipped with a Z-wave standard automation system chip), to which, in turn, the following equipment must be connected:

  • outdoor temperature T sensor (Pt1000 type - installed outside the house);
  • two clamp-on temperature sensors T1 and T2 (type Pt1000 - installed on the flow and return pipes heating circuit);
  • pressure sensor P (type OWEN PD100 or similar - the sensor is installed in a tee with a socket for the sensor, embedded in the boiler circuit);
  • pulse output a gas meter (a low-frequency pulse sensor (reed switch) of the IN-Z61 type is connected to a gas meter, for example BG-10, or it is possible to use a meter already equipped with a pulse output);
  • boiler control contacts (connection terminals are shown in fig. 3, 5 and 6).

The data collection module is designed for simultaneous work with 5 different sensors, transmission of measurement results via a wireless Z-Wave network and is able to control one external device (has one switching relay). The use of the data acquisition module simplifies the process of equipment installation, and also reduces the number of wires to be laid for connecting sensors. Instructions for configuring the data collection module are posted on the manufacturer's website:.

The use of the data collection module makes it possible to include in the “smart home control system” remote control of a gas boiler, remote control of parameters in the heating circuit and monitoring of gas consumption.

The home automation network of the Z-wave standard is controlled by a controller, which can be a Raspberry Pi single-board computer (with an installed RaZberry expansion board) or Fibaro Home Center 2. The boiler automation block diagram is shown in Fig. 2.

Figure 2. Block diagram of boiler automation

The data collection module is connected to five input channels: two patch temperature sensors T1 and T2, an outside air temperature sensor T, a pressure sensor P and a pulse output of the meter. The process of configuring the channels of the data acquisition module and the types of supported sensors are given in the instructions for the module:. Temperature sensors require installation on metal pipe, or to metal parts: fittings, sensors, etc. In this example, one T1 temperature sensor is installed on the supply line, the second T2 sensor is installed on the "return" line.

To monitor the integrity of the heating circuit, a pressure sensor is installed in the system, connected to the data acquisition module.

In addition to remote monitoring, temperature and pressure sensors can be useful in identifying some possible malfunctions: leaks, malfunctions of boiler equipment, etc. (for example, failure expansion tank can lead to a sharp change in pressure in the system, and vice versa, a gradual decrease in pressure indicates a leak from the boiler circuit). Also, a sharp increase in temperature after turning on the boiler may indicate a malfunction of the heat exchanger or circulation pump (which in turn indicates a pre-emergency state of the boiler).

The data collection module and the sensors connected to it via wired interfaces are installed in the boiler room. The data acquisition module communicates with the Z-wave network controller via a radio channel. The boiler control contacts (see Fig. 3, 5 and 6) are connected to the DA1 switching relay of the data acquisition module. In the cases considered ( model lines Main5, Luna 3 Comfort and Luna Duo-Tec MP), the connection is made to the connection terminals of the external (room) thermostat; in this case, it is necessary to remove the jumper (installed by the manufacturer). In fig. 4.1 and 5.1 show cutouts of connection diagrams from the technical documentation of the boiler manufacturer. In fig. 4 and 6 are shown appearance controllers of Baxi Luna 3 Comfort 240 FI and Main5 24 F boilers, respectively.

Figure 3. Connection of the control contacts of the Baxi Luna Duo-Tec MP boiler

Figure 4. General form boiler controller Baxi Luna 3 Comfort 240 FI

Note: in the boiler seriesLuna 3 Comfortthe manufacturer does not need to install the jumper; the relay of the data acquisition module should be connected to the terminals shown in Fig. 4.

Figure 4.1. Boiler connection diagram Baxi Luna 3 Comfort 240 FI

Figure 5. Connection of the control contacts of the Baxi Main5 24 F boiler

Figure 5.1. Baxi Main5 24 F boiler connection diagram

Figure 6. General view of the boiler controller Baxi Main5 24 F

Activation of the relay of the data acquisition module provides the so-called “heat demand”, i.e. transferring the boiler to the heating circuit heating mode and heating the coolant to the set temperature. Accordingly, opening the relay leads to the transfer of the boiler to the DHW heating mode.

The Fibaro wireless leakage sensor is connected via radio directly to the controller. The wireless leakage sensor is powered by a built-in battery, is able to inform about the state of charge, and has a built-in warning light / sound alarm.

The data collection module and the sensors connected to it are installed in the boiler room (except for the external temperature sensor T). The data acquisition module communicates with the Z-wave network controller and the Fibaro leakage sensor via a radio channel.

RaZberry

Instructions for setting up and operating the controller are posted at the link:.

When using RaZberry as a Z-Wave network controller, it may be necessary to pre-configure the equipment, which should be carried out in the following order:

  1. Add (if necessary, if not in your controller) a file describing the NEVOTON DCM-5.1.1-Z device. To do this, the NEVOTON DCM-5.1.1-Z.xml file must be downloaded from the manufacturer's website using the link and added to the folder:

/ opt / z-way-server / ZDDX on your RaZberry Pi.

After that, run the command:

  1. Configure the data acquisition module to work with the installed sensors according to the table:
  1. To convert sensor readings (if necessary) into the desired physical. value according to the formula: "Sensor value * Multiplier + Threshold", install and configure the module for converting physical quantities (DataSensorMultiplication - English name). You can download the converter from the manufacturer's website at the link:

Now you can configure a “virtual room” with installed and connected sensors in the “Smart Home” Z-wave interface.

Figure 7. Z-wave "Smart Home" interface

In fig. 7 shows an example of displaying sensor readings in the "Smart Home" environment. After installing and configuring the "Physical quantities conversion module", the readings of the pressure sensor and gas meter are converted to the usual units of measurement.

Also, the Z-way-server allows you to install the Climate Control module from the Online Apps (see Fig. 8), which is, in fact, a “virtual thermostat”. Like a regular thermostat, the Climate Control module will maintain the set temperature by turning the boiler on to heating the heating circuit. An example of setting up the "Climate Control" module is shown in Fig. nine.

Figure 8. "Climate Control" module

Figure 9. Configuring the "Climate Control" module

Equipment setup and software to work with the controllerFibaro Home Center 2

Unlike the RaZberry controller, Fibaro Home Center 2 has an intuitive interface that clearly displays the status of the equipment and the received data. An example of the graphical interface of the Fibaro Home Center 2 controller is shown in Fig. ten.

We offer to buy Automation for Baxi boilers in our online store in Moscow. Among the large assortment presented in the catalog, other equipment for home, summer residence or cottage is always available. By making a purchase from us, you will receive the following benefits:

  • an individual approach to each client at all stages of cooperation, from assistance in selecting the optimal model and ending with delivery, installation and assistance with warranty service. If you have not found the necessary equipment among the offered assortment, we will do our best to satisfy your request;
  • delivery of the selected product safe and sound is carried out within Moscow and the Moscow region within the time frame agreed with the client. It is also possible to send an order to any region of Russia by transport company chosen by the client;
  • cooperation with leading domestic and foreign manufacturers allows us to offer good prices for the entire range of equipment such as Baxi boiler automation;

Automation for Baxi boilers and other products presented in the catalog are provided with a manufacturer's warranty, the period of which varies depending on the brand and model.

http: //www.site- a reliable partner you can trust.

DELIVERY | We also offer prompt delivery of your order in Moscow and anywhere in Russia.

We work with leading transport companies.

PAYMENT METHODS
  • cash
  • cashless payments
  • bank cards: VISA, MASTERCARD, MIR.

The Italian brand Baxi has been known in Russia for over 15 years. 9 out of 10 specialists in heating and water heating technology are ready to recommend its products. The manufacturer's products are distinguished by impeccable build quality and long service life. Wall-mounted gas boilers Baxi heat private households, apartments, offices and many other premises where you need to create a comfortable and warm atmosphere.

The Baxi brand is rightly associated with reliability and quality. Wall-mounted gas boilers from this brand are famous for being extremely hardy. They are able to work in any conditions, including with reduced gas pressure in the pipeline. Key advantages of Baksi wall-mounted boilers:

  • Separate heat exchangers in most models;
  • Precise maintenance of the DHW temperature;
  • Composite hydraulic groups;
  • Smooth silent ignition;
  • Ability to work on liquefied gas;
  • Electronic flame modulation;
  • Full adaptation to Russian conditions;
  • Fully automatic operation;
  • The ability to work with warm floors.

Wall mounted gas boilers Baxi are compact. They take up a minimum of space and contain everything you need for space heating and preparation hot water... Both single-circuit and double-circuit models are on sale. Double-circuit samples are built on the basis of separate or bithermic heat exchangers. Also, boilers are divided into atmospheric (with an open combustion chamber) and turbocharged (with a closed combustion chamber).

V wall-mounted boilers Baxi uses time-tested metal and composite assemblies. Careful selection of assembly materials ensures the equipment has a long service life and does not require unnecessary frequent maintenance. Depending on the model, Baksi boilers are equipped with turbine flow sensors, weather-dependent automation (in almost all models), remote control panels, as well as boilers for preparing hot water. They remain operational in the event of fluctuations in the supply voltage, record errors in memory, and can work with solar collectors... Numerous sensors are responsible for the safety of the equipment - they control the temperature of the coolant, monitor the draft, prevent overheating of the water in the DHW circuit, and monitor the presence of a flame in the combustion chamber. Also, Baxi boilers are equipped with blocking protection systems. circulation pumps and three-way valves.

You can buy wall-mounted gas boilers Baxi in Teplodvor online store. Our advantages are a large selection of models, fast delivery in Moscow and anywhere in Russia. We will give advice on the assortment, offer accessories and optional equipment for the installation of heating and water treatment systems.

Similar publications